Graco P39LCS Manual De Usuario

Descargar
Página de 40
Setup
312376L
11
Setup
Wet Cup
Before starting, fill the wet cup (R) 1/3 full with Graco 
Throat Seal Liquid (TSL) or compatible solvent. 
Torque Wet Cup
The wet cup is torqued at the factory; however, throat 
packing seals on Severe Duty pumps may relax over 
time. Check wet cup torque frequently after initial 
start-up and periodically after the first week of produc-
tion. Maintaining proper wet cup torque is important to 
extending seal life. 
To torque the wet cup, use the following steps.
2. Use the packing nut wrench (supplied) to torque the 
wet cup; see the following table for torque values. 
Do this whenever necessary. Do not overtighten the 
wet cup.
The enclosed wet cup has a fill port in the cover.
MaxLife pumps use a special u-cup throat seal that 
is non-adjustable and does not require periodic 
torquing.
Displacement Pump Torque
100cc, 60cc
28-44 ft-lbs (38-59 N•m)
200c, 250cc, 500cc
95-115 ft-lbs (128-155 N•m)
F
IG
. 5
R
ti10514a