MAINTENANCE 
CUTTER 24V   86039070   04/10/07 
4-4 
 
CHECKING BATTERY SPECIFIC GRAVITY 
Use a hydrometer to check the battery specific 
gravity.   
 
 
 
 
 
 
 
 
 
 
CHECKING GRAVITY 
A.  Hydrometer 
B. Battery 
NOTE:  Do not take readings immediately after 
adding distilled water, if the water and acid are not 
thoroughly mixed, the reading may not be accurate. 
 
Check the hydrometer readings against this chart. 
SPECIFIC GRAVITY 
@ 80
°
 F (27
°
C) 
BATTERY CONDITION 
1.265 100% 
CHARGED 
1.225 75% 
CHARGED 
1.190 50% 
CHARGED 
1.155 25% 
CHARGED 
1.120 DISCHARGED 
NOTE:  If the readings are taken when the battery 
electrolyte is any temperature other than 80
°
(27
°C), the reading must be temperature corrected. 
 
To find the corrected specific gravity reading when 
the temperature of the battery electrolyte is other 
than 80
°F (27°): Add (+) to the specific gravity 
reading 0.004 (4 points), for each 10
°F (6°C) above 
80
° (27°C).   
Subtract (-) from the specific reading 0.004 (4 
points), for each 10
°F (6°C) below 80°F (27°C). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
TO CHARGE THE BATTERIES 
 
 
When servicing machine, avoid contact with 
battery acid. 
 
 
Batteries emit hydrogen gas.  Explosion or fire 
can result.  Keep sparks and open flame away.  
Keep covers open when charging. 
 
 
Wear eye protection and protective clothing 
when working with batteries. 
 
 
Charge batteries in a well ventilated area.  Leave 
the battery cover open. 
 
Use a 24 volt, 18 amp maximum output or 25 amp 
(depending on the size of the batteries), DC charger 
which will automatically shut off when the batteries 
are fully charged. 
 
1.  Stop the machine in a clean, well ventilated area 
next to the charger.  w 
2.  Turn “OFF” machine. 
 
FOR SAFETY:  Before leaving or servicing 
machine; stop on level surface, turn off machine 
and remove key. 
 
3.  
Raise the battery cover. 
 
 
Batteries emit hydrogen gas.  Explosion or fire 
can result.  Keep sparks and open flame away.  
Keep covers open when charging. 
 
4.  
Check the electrolyte level in each battery cell.  
Before charging, add just enough distilled water 
to cover the plates.  After charging is complete, 
add just enough distilled water to bring up the 
level to the indicator ring.  If the water level is 
too high before charging, normal expansion rate 
of the electrolyte may cause an overflow. 
Resulting in a loss of battery acid balance and 
damage the machine. 
 
 
 
!
WARNING
!  
 
CAUTION
!  
 
WARNING
!  
 
WARNING
!  
 
WARNING
 
 
Battery Check