MAINTENANCE 
CUTTER 24V   86039070   04/10/07 
4-5
 
 
5.  Replace the battery caps, and leave them in 
place while charging. 
6.  Unplug the battery connector from the machine. 
 
FOR SAFETY:  When charging, connect the 
charger to the batteries before connecting the 
charger to the AC wall outlet.  Never connect the 
charger to the AC wall outlet first.  Hazardous 
sparks may result. 
 
7.  
Plug the charger connector into the battery 
connector.  Connect the charger AC plug to a 
wall outlet.  The charger gauge should indicate 
that the batteries are charging.  
8.  When the batteries are fully charged, disconnect 
the charger from the AC wall outlet, then 
disconnect the charger from the batteries. 
9.  Connect the batteries to the machine connector. 
10.  Check the electrolyte level.  It should be up to 
the indicator ring.  If necessary, add distilled 
water. 
11.  Lower the battery cover. 
 
 
Machines equipped with Onboard Charger: 
 
1.  
Connect charger’s AC power cord to AC mains.  
The charger’s YELLOW “AC” LED will light. 
 
 
 
Note:  When charger is energized, all machine 
function will shut down. 
 
2.  
Current level being delivered to the batteries will 
be displayed on the charger’s bar graph. 
 
3.  When battery charge level has reached 80% the 
YELLOW “80%” LED will light. 
 
4.  Batteries will then receive a low current “finish-
charge” indicated by the flashing GREEN 
“100%” LED. 
 
5.  Charging cycle is complete when “100%” LED is 
continuously GREEN. 
 
6.  Disconnect charger’s AC power cord. 
 
7.  Raise battery cover and check the battery 
electrolyte level.  It should be up to the indicator 
ring.  If necessary, add distilled water. 
 
8.  Lower the battery cover. 
 
Note:  For additional information about battery 
charger function, please see the charger Product 
Manual.
 
 
 
CHANGING BATTERIES 
Stop the machine in a clean area next to the 
charger.  Turn off machine. 
 
FOR SAFETY:  
Before leaving or servicing the 
machine; stop on level surface, turn off machine 
and remove key. 
 
1.  
Raise the battery cover. 
2.  Disconnect battery pack from machine. 
3.  Use the proper size open end wrench to 
disconnect main ground wire first and secure 
cable terminal away from batteries. 
4.  Disconnect main positive lead and secure cable 
terminals away from batteries. 
5.  Loosen both terminals on each jumper cable 
and remove one at a time. 
6.  Prepare a suitable site to place the batteries. 
7.  Attach suitable battery lifting device and lift 
batteries from the machine. 
 
 
 
Batteries are a potential environmental hazard.  
Consult your battery supplier for safe disposal 
methods. 
!  
   
WARNING 
RED
BLK
-
-
BLK
-
RED
RED
RED
-
BLK
 BLK
-
 BLK
RED
RED
 BLK
+
+
+
+
+
+
-