3com DUA3700-0BAA04 Manual De Usuario

Descargar
Página de 142
E-4
A
PPENDIX
 E: C
ABLING
 R
EQUIREMENTS
Damaged Transceiver Due to Excessive Insertion Force
The ATM specification for insertion force on the connector into an ATM 
SC receptacle is 3.5 lbs. However, it is possible to exert up to 30 lbs. of 
insertion force on the transceiver if you are too forceful while inserting 
the SC connector into the receptacle. This can cause failure of the 
transceiver's mechanical joints, permanently damaging the part and 
disabling the port.
When inserting connectors into the ATM ports, gently insert the SC 
connector into the receptacle until you hear the connector click into 
place. Use only enough force to engage the connector in the receptacle - 
no more than 3.5 lbs. This will avoid damage to the transceiver.
Multi-mode Fiber
Standards
The MMF-PMD standards define the requirements for an ATM cable plant 
to support an interstation distance of up to 2 kilometers (1.25 miles) of 
multi-mode fiber. The cable plant includes all fiber optic components 
between any two communicating ATM devices and their associated 
“station-to-network” connectors at each end.
To determine whether the cable plant complies with the MMF-PMD 
standard, do the following:
Compare the specifications of the fiber you are using to standard 
specifications, as described in Table E-1 and Table E-2.
If unlike fibers are mated in the cable plant, calculate insertion losses to 
see whether they exceed the maximum attenuation value allowed for a 
link, as described in Table E-3 and Table E-4.
Verify that the fiber's modal bandwidth is within an acceptable range for 
the length of the link, as described on page E-7.
The following sections describe each of these steps and give examples.
Comparing Fiber to Specifications
Compare the specifications of the fiber you are using to those in the 
following tables. If the fiber does not meet the specifications, use a 
different fiber or contact 3Com's Technical Support.
The fiber you use must meet the specifications listed in Table E-1, which 
describes the standard set forth in MMF-PMD. Table E-2 describes 
62.5/125 cable, commonly sold as “ATM Spec,” which meets all the 
requirements of the MMF-PMD standard.