ATM Cabling
E-5
*Maximum attenuation includes cable attenuation and the loss induced 
by other components such as connectors, splices, and the mating of 
unlike fiber types. Although some 2 km cable plants have a total 
attenuation of less than 11.0 dB, the 2 km interstation distance must be 
maintained to comply with modal bandwidth requirements.
Calculating Insertion
Losses for Unlike
Fibers
If unlike fibers are mated in the cable plant, calculate insertion losses to 
be certain that the cable plant does not exceed the maximum attenuation 
value listed in Table E-1. To calculate the insertion loss, consider the types 
of fiber in the cable plant and the connectors or splices used to join them. 
Compare the result to the maximum attenuation value listed in Table E-1. 
If the result is greater than the value in the table, use only like fibers in the 
cable plant.
Table E-1   Standard Multi-mode Fiber Specification
Specification
Description
Core
62.5 µm diameter
Cladding
125 µm diameter nominal
122 µm minimum
128 µm maximum
Numerical aperture
0.275
Maximum attenuation
11 dB* (1dB allowed for reflection and 
dispersion penalties.)
Modal bandwidth
500 MHz. km
Maximum distance between nodes
2 km
Output power (from transmitter)
19 dB minimum
14 dB maximum
Receive power
30 dB minimum sensitivity
14 dB maximum sensitivity
Table E-2   Alternate Multi-mode Fiber Types
Core (µm)
Cladding (µm)
Numerical Aperture
50
125
0.20
50
125
0.22
85
125
0.28
100
140
0.29