3com DUA3700-0BAA04 Manual De Usuario

Descargar
Página de 142
Switch Module
4-9
Preparatory Steps
Carry out the following preparatory steps.
Install main and redundant switch modules in the switch module slot 1 
and slot 2 respectively (see “Installing a Switch Module” on page 4-5). Do 
not run the Integrated Fast Setup yet.
Each time the switch is rebooted during this procedure the cards change 
roles. The main card becomes the redundant card and vice versa. The 
main card can always be identified by its ACT LED flashing once every 
two seconds. The ACT LED of the redundant card flashes at a lower rate.
Verify that at least one interface card of any type is installed in the 
CoreBuilder chassis in any interface card slots 3-6. Data is transferred 
between switch modules via a communications chip on an interface card.
Verify that the Ethernet management ports in both switches are 
connected to the NMS station. They can either be connected through a 
hub to the NMS station or through an Ethernet interface card in the same 
chassis, such as the CoreBuilder 7400 High Density Ethernet/ATM 
interface card, to the NMS station. 
During the procedure you will need to verify connectivity between the 
NMS station and the switch by pinging the switch module from the NMS 
station. 
Connectivity between the switch module and its attached devices is 
established by an RARP transmitted by the switch module when it boots. 
The RARP causes a device to learn the MAC address of the switch 
module. However, there are certain devices, for example, a Solaris station, 
which will not learn a new MAC address for an IP when one already 
exists. If you are using one of these devices as an NMS station, and you 
are unable to ping the switch module, try erasing the switch module’s 
MAC address from the device’s ARP table and ping again.
Verify that the RS-232 terminal line is connected to the console port on 
the main switch module.
Procedure Execution
Reset the configuration of both switch modules by executing the 
RESETCFG.BAT file supplied with your software. 
Do not use the LMA menu (1) SYS / (2) RES to reset the switch module 
configuration.