3com DUA3700-0BAA04 Manual De Usuario

Descargar
Página de 142
4-10
C
HAPTER
 4: I
NSTALLING
 
AND
 C
ONNECTING
 C
ORE
B
UILDER
 M
ODULES
To execute the RESETCFG.BAT file proceed as follows:
Perform the LMA command (1) SYS / (3) LOA / (3) LCL / 1 to put the 
system in Load Mode: Load.
Reboot the switch using the LMA menu command: (1) SYS / (7) RBO. 
The switch will reboot in debug mode.
Transfer the RS-232 cable to the service port of the main switch 
module.
From a DOS window on the LMA terminal execute
resetcfg  com   speed
where “com” is the communications port you are using and “speed” 
is 115200 for a CoreBuilder 7000HD switch module and 57600 for a 
CoreBuilder 7000 switch module.
Transfer the RS-232 cable to the service port of the redundant switch 
module.
f
Repeat step d)
Transfer the RS-232 cable to the console port of the main switch 
module. 
Switch Module Redundancy Setup
Set up the main switch module using the Integrated Fast Setup (see 
“Integrated Fast Setup” on page 6-3). Do not reboot the switch from the 
Integrated Fast Setup procedure (answer “no” to the prompt). 
The main menu appears.
Wait for one minute to allow the configuration data to transfer from the 
main switch module to the redundant switch module.
Reboot the switch using the LMA menu sequence: (1) SYS / (7) RBO. This 
causes the configuration data to be recorded in flash memory and also 
causes the redundant switch module to become the main switch module.
After the switch reboots, answer “no” to the prompt: “Do you wish to 
erase the setup parameters”. 
Run the Integrated Fast Setup procedure as in step 2) to verify that the 
setup parameters have been transferred correctly to the second switch 
(the Integrated Fast Setup procedure now displays the setup parameters 
resident in the second switch module). Press Enter repeatedly to verify 
these parameters; do not enter new values.