3com DUA3700-0BAA04 Manual De Usuario

Descargar
Página de 142
Switch Module
4-11
Verify that the ELAN names in the LECS database are identical in both 
switch modules. Use menu item (2) LEM/(1) LCS/(5) LNT to check that the 
LECS database of the second switch includes the ELAN name of the first 
switch. For example, Elan6666_0 - Elan6666_15 
LANE Redundancy Setup
Verify connectivity between the switch module and the NMS station by 
pinging the switch module from the NMS station. 
Load the Transcend application and open the Wizard Tool from the 
ATMvLAN tool bar 
10 Open the Backbone and Services Window.
11 Configure the LECS order as desired and press the Apply button. 
12 Configure the LECS database. Add all the primary and redundant ELAN 
names desired to the LECS database and press Apply. Make a list of the 
ELAN names you have selected. You will need them for setting up the 
other switch module.
13 When finished, close the Backbone and Services window.
14 Wait one minute to allow the LECS order database to transfer to the 
other switch module. 
The LECS ELAN database does not transfer automatically.
15 Reboot the switch using the LMA menu sequence: 
(1) SYS / (7) RBO
The purpose of this step is to make the first switch module active in order 
to set up the LANE services there.
16 After the first switch boots, check its connectivity with the NMS station as 
in step 8).
17 Perform steps 10) and 12) using the same list of ELANs.
18 Wait one minute.
Verifying LANE Redundancy Setup
19 Use the MIB browser under the Transcend tools menu and browse 
through the MIB to verify that all the information regarding the LECS 
order list has been transferred correctly. 
Look in the following MIB location:
private.
enterprises.
atmForum.