Electrical Specifications of Alarm Input 
Terminals
(TK-C215VP12U/E only)
● To prevent penetration of noise in the internal 
circuitry, apply a non-voltage contact signal to 
the ALARM input terminal. Never apply a 
voltage.
● Apply an alarm signal for at least 200 ms. If it is 
shorter, it is not guaranteed that the signal will 
be recognized as an alarm signal.
● Under the alarm status (status when the metal 
contact is “make”), select the contact or 
connecting wire such that the maximum wire 
resistance between the ALARM IN and 
ALARM GND is within 150 
K.
‹ Polarity of alarm signals
ALARM INPUT
SHORT (CONTACT)
ALARM
OPEN
NORMAL (HOME POSITION)
ALARM IN
ALARM GND