Bosch 550 Manual De Usuario
62
en |
MIC Series 550 Camera
F.01U.239.454 | 3.0 | 2012.09
User Manual
Bosch Security Systems, Inc.
A.3
Preset Commands (Forward Vision Protocol)
0 - Pattern
Press and hold
(2 seconds)
Initiates recording based upon current Recording
setting (A or B) in the Setup Menu. Press ACK to end
recording.
Press
Initiates recording continuous playback based upon
current Recording setting (A or B) in the Setup Menu.
1 - Pattern
Press and hold
(2 seconds)
Initiate Recording A. Press ACK to end recording.
Press
Initiate Recording A continuous playback
2 - Pattern
Press and hold
(2 seconds)
Initiate Recording B. Press ACK to end recording.
Press
Initiate Recording B continuous playback
3 - Pattern
Press
Initiate the AutoDome standard preset tour (Tour 1)
4 - Pattern
Press
Initiate the AutoDome custom preset tour (Tour 2)
1 - Aux On / Aux Off Press
Activates / deactivates selected wiper mode or Alarm
Output 1.
2 - Aux On / Aux Off Press
Activates / deactivates alarm output 2
3 - Aux On / Aux Off Press
Activates / deactivates alarm output 3
4 - Aux On / Aux Off Press
Activates / deactivates alarm relay
91 - Aux On
Press
Activate Zone Scan (display zone titles)
92 - Aux On
Press
Activate Zone Scan (display zone titles)
Keyboard
Command
User Action
Description
Preset
Number
Command
Description
1
Auto Home Position
After a certain amount of time--programmable--with no
manual control, the camera moves to the home
position (Preset 1). When this function is turned off,
the camera remains stationary until the next user input.
62
Wash Wipe Position
If Wash Wipe is On, then, when the Wash auxiliary is
set, the camera returns to a preset Wash Position,
activates the washer relay in the PSU, and turns on the
wiper. When the auxiliary is off, the camera returns to
its prior position and turns off the wiper. If Wash Wipe
is Off, then, when the aux is activated, the camera
closes the washer relay and remains in its current
position.
85
On Screen menu
Displays the On Screen Menu.
86
Self Diagnosis
Runs rudimentary tests indicating any faults with the
unit. The test begins with the unit moving to a specified
test position and then checking for valid resolver
readings and reliable camera module communications.
Then, the pan and tilt drives and camera zoom are
tested. Finally, the wiper is activated. The results of
each test are displayed as completed.
87
Play Pattern One
Play Pattern 1
88
Stop Pattern One
Stop Pattern
89
Record Pattern One
Record Pattern 1
90
Play Pattern Two
Play Pattern 2
91
Stop Pattern Two
Stop Pattern 2
92
Record Pattern Two
Record Pattern 2