•  Auto Recovery:  Enables/Disables the Auto Recovery feature for the 
selected unit.  When both Load Shedding and Auto Recovery are enabled, the 
Outlet Managed PDU will return plugs to their former On/Off state after the 
temperature falls below the Alarm Clear Threshold value.  This allows the 
Outlet Managed PDU to "undo" the effects of the Load Shedding feature after 
the temperature returned to an acceptable level.  (Default = Off.)
•  Plug Access:  Determines which Plug(s) will be switched when the 
temperature exceeds the Alarm Set Threshold and Load Shedding is 
triggered.  For example, if plugs A1, A2 and A3 are selected, these plugs 
will be switched On or Off whenever the temperature exceeds the Alarm Set 
Threshold.  (Default = undefined.)
•  Plug Group Access:  Determines which Plug Group(s) will be switched 
when the Load Shedding feature is triggered.  (Default = undefined.)