TROUBLESHOOTING GUIDE - Observe Safety Guidelines detailed in the beginning of this manual.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
TROUBLESHOOTING AND REPAIR
F-5
F-5
POWERARC® 5500
OUTPUT  PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
No weld output and no auxiliary out-
put - engine runs normally.  
1.  Perform the 
2.  The field capacitor (C1) or bridge
(D1)  may  be  faulty.    Test  or
replace.
3.  Test  the  rheostat  (R1).    Normal
resistance is 3.3 ohms.
4.  The rotor may be faulty.  Per form
1.  The  generator  brushes  may  be
worn  or  faulty.    See  the  Main -
tenance section of this manual or
contact  your  local  Lincoln
Electric  Authorized  Field  Ser -
vice Facility
.