TROUBLESHOOTING GUIDE - Observe Safety Guidelines detailed in the beginning of this manual.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
TROUBLESHOOTING AND REPAIR
F-7
F-7
POWERARC® 5500
OUTPUT  PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
No auxiliary power - welding output
is normal - engine runs normally.
1.  Check  the  auxiliary  power  re -
ceptacles  and  associated  wires
for loose or faulty connections.  
2.  Check the continuity (zero ohms)
of leads 3, 3A, 3B; 6, 6A, 6B, 6C;
and  5,  5A,  5B  from  the  recepta-
cles to the stator windings.  See
the Wiring Dia gram.
3.  Make  sure  lead  5  (white)  is
grounded  to  the  machine  frame
(zero ohms).
4.  Check  for  an  open  or  grounded
auxiliary  winding  in  the  stator,  6
to 3.  See the Wiring Diagram.
1.  Check  circuit  breakers  CB1  and
CB2.  Reset if tripped.
2.  Make sure that the control rheo-
stat (R1) is set at “GENERATOR”
(maximum).
3.  Check for loose or faulty plug at
power receptacle.