If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3878.
CAUTION
TROUBLESHOOTING AND REPAIR
F-9
F-9
VRTEX 
TM
360
FUNCTION PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
The  user  is  not  receiving  any
visual  or  audio  feedback
information in the helmet (FMD).
Make sure the Helmet (FMD) is
connected properly.
Check  the  USB  connection
between the Polhemus Interface
Module and the CPU for loose
or faulty connections.
Check the USB connections
between  the  Polhemus
Interface Module and the CPU
for loose or faulty connections.
Make sure the FMD Control
Unit is are receiving the 5VDC
supply voltage.  See the wiring
diagram.
Make sure the FMD Control
Unit is turned on.
If  the  5VDC  supply  is  not
present  perform  the  5VDC
Supply Test. 
The FMD may be faulty.
The CPU may be faulty.
Check for loose or faulty con-
nections (ribbon cable)
between the User Interface
Digital I/O Module and the ter-
minal block interface.  See
wiring diagram
(Continued)