Lincoln Electric SVM200-A Manual De Usuario

Descargar
Página de 171
CAUTION
TROUBLESHOOTING AND REPAIR
F-10
F-10
VRTEX 
TM
360
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3878.
FUNCTION PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
The  VRTEX
TM
360  does  not
function correctly in the SMAW
(stick)  mode.    But  it  functions
correctly in the VR GMAW mode.
Make certain the SMAW (stick)
electrode device is connected
properly.
Make sure the correct welding
procedures are set.
Check  for  loose  or  faulty
connections between the Motor
Control PC Board and the VR
SMAW Device.  See the wiring
diagram.
Check  for  loose  or  faulty
connections between the Motor
Control  PC  Board  and  the
Relay  PC  Board.    See  the
wiring diagram.
Make sure the Motor Control
PC  Board  is  receiving  the
12VDC supply from the Relay
PC Board.  Check at leads #72
to #73.  If the 12VDC is not
present the Relay PC Board
may be faulty.  See the wiring
diagram.
Check  for  loose  or  faulty
connections  at  the  ribbon
cable, between the USB Digital
I/O Module and the terminal
block interface.  Also check
between  the  terminal  block
interface and the Relay Board.
See the wiring diagram.
Perform the Interface Digital
Module IO Test.
The VR SMAW device may be
faulty.