ATTO Technology Inc. iPBridge Installation and Operation Manual
 7.1.3  Maintenance commands
The CLI commands outlined in this chapter may be used to get information or perform functions which 
are used in a variety of situations with the ATTO iPBridge.
Date
Sets the date for the iPBridge if SNTP has been disabled 
or is not available.
Set syntax: set Date [MM] / [DD] / [YYYY]
Requires a SaveConfiguration command
Get syntax: get Date
FirmwareRestart
Causes the iPBridge to reboot, then re-initialize its 
firmware.
Immediate command: FirmwareRestart
MaxOpTemp
Establishes/reports the maximum enclosure temperature 
alarm in degrees Celsius. If the temperature of the 
iPBridge rises above the maximum MaxOpTemp, thermal 
control event handling occurs.
Valid entries are between 55 and 70 degrees C
Default: 70
Set syntax: set MaxOpTemp [55-70]
Requires a SaveConfiguration command
Get syntax: get MaxOpTemp
MinOpTemp
Establishes/reports the minimum enclosure temperature 
alarm in degrees Celsius. If the temperature of the 
iPBridge falls below the minimum MinOpTemp, thermal 
control event handling occurs. Valid entries are between 
0 and 15 degrees. 
Default: 0
Set syntax: set MinOpTemp [0-15]
Requires a SaveConfiguration command
Get syntax: get MinOpTemp
OpTempWarn
Controls the number of degrees in Celsius before a 
thermal control event handling occurs. Warnings are 
made via system log entries. Valid entries are between 0 
and 15 degrees.
Default: 5
Set syntax: set OpTempWarn [0-15]
Requires a SaveConfiguration command
Get syntax: get OpTempWarn
Password
Specifies a password for all sessions: NDMP, telnet, 
FTP and ExpressNAV web-based interface. A 
prompt asks for the current password, to enter the 
new password, and to confirm the new password. 
Passwords are case sensitive, 0-32 characters with 
no spaces. An empty password can be configured by 
entering the Password confirmation prompts with no 
parameters. The command RestoreConfiguration 
default
 sets the password to its default value.
Default: Password
Set syntax: set Password 
Requires a SaveConfiguration command
Reserve
Reservation of the iPBridge is implicit: once the 
configuration image is changed by any user of services, 
the iPBridge becomes RESERVED. Executing a 
SaveConfiguration or RestoreConfiguration 
RELEASES the iPBridge so that other services users may 
access it. When iPBridge services interface is 
RESERVED, set commands from other users are 
unavailable. 
At least one interface must always have access to the 
iPBridge. 
Immediate command: Reserve
RestoreConfiguration
Restores configuration to either the default configuration 
or the configuration last saved into non-volatile memory. 
The saved option undoes any changes made since the last 
save.
Immediate command: RestoreConfiguration [Default | 
Saved]
SCSIPortReset
Resets the specified SCSI bus.
Immediate command: SCSIPortReset [sb]