Chapter 5 Parameters|VFD-S Series 
5-50
 
Revision August 2008, SE09, SW V2.61
 
Example 5 (Pr. 5-07 = d1 Execute one cycle of the PLC program): 
In this example, the PLC program runs continuously.  It should be noted that the times of reserve 
motion may be shorter than expected, due to the acceleration/deceleration times. 
Frequency
60Hz
50Hz
40Hz
30Hz
20Hz
15Hz
10Hz
0Hz
Time
(Sec)
FWD
REV
5-09
Master freq.=5Hz
5-00=10 Hz
5-01=20 Hz
5-02=40 Hz
5-03=60 Hz
5-04=50 Hz
5-05=30 Hz
5-06=15 Hz
4-07=d17
3-05=d10
3-06=d11
5-07=d1
5-08=d68
5-09=10
5-10=10
5-11=12
5-12
 Sec
 Sec
 Sec
=15 Sec
5-13=15 Sec
5-14=8 Sec
5-15=17 Sec
5-16=17 Sec
* The calculation of time for Pr.5-11, Pr.5-12, Pr.5-15 and Pr.5-16 should be carefully planned.
 
 
5-08 
PLC Forward/Reverse Motion 
Unit: 1
 
Settings 
d0 to d255 
Factory Setting: d0
 
This parameter controls the direction of motion for the Multi-Step Speed Pr.5-00 to Pr.5-06 
and the Master Frequency.  The original direction of Master Frequency will become invalid. 
NOTE
 
The equivalent 8-bit number is used to program the forward/reverse motion for each of the 8 speed 
steps (including Master Frequency). The binary notation for the 8-bit number must be translated into 
decimal notation and then be entered. 
1
2
3
4
5
6
7
Weights
Bit
0=Forward
1=Reverse
Direction of 1st
Pr.5-00
 speed for 
Direction of 2nd
Pr.5-01
 speed for 
Direction of 3rd
Pr.5-02
 speed for 
Direction of 4th
Pr.5-03
 speed for 
Direction of 5
Pr.5-04
th speed for 
Direction of 6
Pr.5-05
th speed for 
Direction of 7
Pr.5-06
th speed for 
0
Director of Master Frequency during PLC