Delta Electronics VFD-S Manual De Usuario

Descargar
Página de 185
Chapter 5 Parameters|VFD-S Series 
Revision August 2008, SE09, SW V2.61 
5-51
 
1
2
3
4
5
6
7
Weights
Bit
0=Forward
1=Reverse
Direction of 1st
Pr.5-00 =FWD
 speed for 
Direction of 2nd
Pr.5-01 =REV
 speed for 
Direction of 3rd
Pr.5-02 = F
 speed for 
Direction of 4th
Pr.5-03 = F
 speed for 
Direction of 5
Pr.5-04 = F
th speed for 
Direction of 6
Pr.5-05 = REV
th speed for 
Direction of 7
Pr.5-06 = F
th speed for 
0
0
1
0
0
1
1
0
0
Direction
WD
WD
WD
WD
WD
 
The setting value = bit7 x 2
7
+bit6 x 2
6
+bit5 x 2
5
+bit4 x 2
4
+bit3 x 2
3
+bit2 x 2
2
+bit1 x 2
1
+bit0 x 2
0
 
                = 0 x 2
7
+1 x 2
6
+0 x 2
5
+0 x 2
4
+0 x 2
3
+1 x 2
2
+0 x 2
1
+0 x 2
0
 
                = 0+64+0+0+0+4+0+0 
                = 68  
Setting Pr.5-08 as d68. 
 
5-09 
Time Duration of Master Speed 
Unit: 1
5-10 
Time Duration of 1st Step Speed 
Unit: 1
5-11 
Time Duration of 2nd Step Speed 
Unit: 1
5-12 
Time Duration of 3rd Step Speed 
Unit: 1
5-13 
Time Duration of 4th Step Speed 
Unit: 1
5-14 
Time Duration of 5th Step Speed 
Unit: 1
5-15 
Time Duration of 6th Step Speed 
Unit: 1
5-16 
Time Duration of 7th Step Speed 
Unit: 1
 
Settings 
d0 to d65500 
Factory Setting: d0
 
Pr.5-10 to Pr.5-16 correspond to operation time of each multi-step speed defined by 
parameters 5-00 to 5-06. The maximum value of these parameters is 65500 sec., and it’s 
displayed as d65.5. 
NOTE
 
If a parameter is set to “d0” (0 Sec), the corresponding step will be skipped.  This is commonly used 
to reduce number of program steps.