Cisco Systems 7500 Series Manual De Usuario

Descargar
Página de 303
R E V I E W   D R A F T — C I S C O   C O N F I D E N T I A L
3-27
Cisco 7500 Series Installation and Configuration Guide
OL-5008-03 B0
Chapter 3      Installing a Cisco 7500 Series Router
  Installing the Cisco 7513, Cisco 7513-MX, and Cisco 7576
Note
When you install the network interface cables, route the cables to and through the 
cable-management bracket. If you are using very thin cables that slip through the bracket 
openings, insert cable ties through the holes in the bracket and wrap them around the cables to 
secure them. 
It might be necessary to bundle longer cables to avoid tangling them. Do this at the 
cable-management bracket or at the rack, but leave enough room to remove processor modules 
and power supplies and to change cables as required. Do not block the power supply or chassis 
intake air vents with cables. Verify that the cables do not interfere with removal and installation 
of the blower module.
This completes the procedure for installing the cable-management bracket. Proceed to the next section, 
.
Installing Cisco 7513, Cisco 7513-MX, and Cisco 7576 Power Supplies
Your Cisco 7513, Cisco 7513-MX, or Cisco 7576 was shipped with the power supplies removed. The 
Cisco 7513 and Cisco 7513-MX are shipped with one power supply as standard equipment; a second 
power supply is optional equipment. When purchased new (not upgraded), the Cisco 7576 comes with 
two AC-input power supplies as standard equipment. Install power supplies only after you have finally 
installed or rack-mounted the chassis. 
Based on the NFPA 70 National Electrical Code, you should use a 35-amp (A) overcurrent protector to 
meet the requirement for the overcurrent protector size of 125 percent of the load current, which is 
approximately 27A. An overcurrent protector rated for 30A can be used only if it has been listed by the 
safety agency for operation at 100 percent of its rating.
Note
The following procedure applies to AC-input and DC-input power supplies, with specific differences 
clearly noted. To prevent system problems, do not mix AC-input and DC-input power supplies in the 
same chassis.
Follow this procedure to install a power supply in the Cisco 7513, Cisco 7513-MX, and Cisco 7576:
Step 1
If possible, turn off the circuit breaker to which you will connect power and tape the breaker switch in 
the off position.
Step 2
Check the switch on the face of the power supply, and place it in the off (O) position. The interlock tab 
should not extend out of the unit.
Step 3
Hold the supply as shown in 
 and slide it into the power supply bay. Push the supply all the 
way into the chassis until the sides are flush against the chassis frame. To prevent damaging the 
backplane connector, do not jam the power supply into the bay.