Cisco Systems 7500 Series Manual De Usuario

Descargar
Página de 303
R E V I E W   D R A F T — C I S C O   C O N F I D E N T I A L
8-15
Cisco 7500 Series Installation and Configuration Guide
OL-5008-03 B0
Chapter 8      Troubleshooting a Cisco 7500 Series Router
  Troubleshooting Guidelines for the Cisco 7513, Cisco 7513-MX, and Cisco 7576
RSP2 processor with 16384 Kbytes of memory
(additional text omitted from this example)
F3: 2012356+47852+194864 at 0x1000
              Restricted Rights Legend
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
              cisco Systems, Inc.
170 Tasman Drive
San Jose, CA 95134
GS Software (RSP-K), Version 10.3(571) [fc3], RELEASE SOFTWARE
Copyright (c) 1986-1995 by cisco Systems, Inc.
(additional text omitted from this example)
Press RETURN to get started!
Troubleshooting the Cisco 7513, Cisco 7513-MX, and Cisco 7576 Power 
Subsystem
This section provides information on troubleshooting the Cisco 7513, Cisco 7513-MX, and Cisco 7576 
power subsystem.
Check the following to help isolate the problem: On the interface processor end of the power supplies, 
are the AC (or DC) OK LEDs on?
If yes, the AC (or DC) source is good, and the power supplies are functional. 
If no, but the blower is operating and LEDs on the processor modules are on, suspect a faulty power 
supply LED. The RSPs use +5 VDC, and the blower uses +24 VDC; therefore, if both the RSPs and 
blower are operating, all internal DC lines are within tolerance.
If no and there is no other obvious activity, first suspect that the power switch is not fully in the on 
(|) position. Rotate the power switch clockwise and ensure that it is set completely in the on (|) 
position. See th
If the system power switch is set correctly and the AC (or DC) OK LED remains off, suspect 
the AC (or DC) source or the power cable. Turn the power switch off, connect the power cable 
to another power source if one is available, and turn the switch back on. If the LED then goes 
on, the problem is the first power source.
If the LED fails to go on after you connect the power supply to a new power source, swap the 
power cable with a replacement if one is available and turn the switch back on. If the AC (or 
DC) OK LED then goes on, return the first power cable for replacement. 
If the LED still fails to go on when connected to a different power source with a new power 
cable, the power supply is probably faulty. If a spare power supply is available, replace the 
existing power supply with the spare and restart the system. See th
 and th
If the AC (or DC) OK LED then goes on, return the faulty power supply for replacement.