R E V I E W   D R A F T — C I S C O   C O N F I D E N T I A L
8-16
Cisco 7500 Series Installation and Configuration Guide
OL-5008-03 B0
Chapter 8      Troubleshooting a Cisco 7500 Series Router
  Troubleshooting Guidelines for the Cisco 7513, Cisco 7513-MX, and Cisco 7576
If you are unable to resolve the problem or if you determine that either the power supply or power cable 
is faulty, contact a service representative for instructions. 
Troubleshooting the Cisco 7513, Cisco 7513-MX, and Cisco 7576 Cooling 
Subsystem
This section provides information on troubleshooting the Cisco 7513, Cisco 7513-MX, and Cisco 7576 
cooling subsystem.
Check the following to help isolate the problem:
When you start up the system, does the blower go on?
To determine if the blower is operating, listen for the blower motor. In noisy environments, place 
your hand near the middle of the plastic panel on the front of the chassis (opposite the interface 
processor end of the chassis) to feel for air being forced out the exhaust vent.
If yes, the +24 VDC line to the blower is good, but there might be a problem with the software.
If no, there is a problem with the blower or the +24 VDC power. If the output fail LED is on, 
there could be a problem with the +24VDC supply to the blower either at the power supply or 
the blower control board.
If no and the output fail LED is off, ensure that the blower module is seated properly. To remove 
and reseat the blower module, see the 
. Ensure that the blower 
control board edge connector is inserted fully in the backplane socket. After you replace the 
chassis cover panel, try starting the system again.
Do the system and blower start up but shut down after about 2 minutes?
If you have changed the software configuration register boot field settings or altered the 
configuration file boot instructions, the system could be booting a software image that does not 
recognize the signals from the blower control board, and therefore assumes that the cooling 
subsystem is not operating. 
If the following message is displayed, it indicates that the blower has failed or is operating out 
of tolerance: 
%ENVM-2-FAN: Fan has failed, shutdown in 2 minutes
If the blower or the blower control board fails, you must replace the blower module. 
If the following message is displayed, it indicates that the system has detected an 
overtemperature condition or out-of-tolerance power inside the chassis: 
Queued messages:
%ENVM-1-SHUTDOWN: Environmental Monitor initiated shutdown
If an environmental shutdown results from an out-of-tolerance power condition, the output fail 
LED will go on before the system shuts down. See the 
Although an overtemperature condition is unlikely at initial startup, ensure that heated exhaust 
air from other equipment is not entering the inlet vents, and that there is sufficient clearance 
around the front and rear of the chassis to allow cooling air to flow. Refer to the guidelines in 
 for preventive site preparation recommendations.