2-5
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide
OL-13208-03
Chapter 2      Cisco ASR 1000 Series Routers Components
  Cisco ASR 1000 Series Route Processor
How the Cisco ASR1000-RP1 Alarm LEDs Work
The Cisco ASR1000-RP1 faceplate displays the CRIT, MAJ, and MIN alarm indicator LEDs. A female 
DB-25 connector on the power supply faceplate enables you to attach an external alarm monitoring 
facility to the router. See 
The alarm signals sent to this DB-25 connector are identical in function to those sent to the system LEDs 
on the Cisco ASR1000-RP1. Each alarm consists of three contact pins that are switched when an alarm 
becomes active which causes a corresponding contact closure between the DB-25 connector pins.
Thus, a critical, major, or minor alarm condition detected in the router can trigger a simultaneous fault 
indication in some of the following ways: 
  •
System alarm LEDs—The three system alarm LEDs on the Cisco ASR1000-RP1 faceplate 
constitute the standard method of alarm notification in the router. These LEDs indicate router status 
at all times, but you must directly observe these LEDs to become aware of a router alarm condition. 
  •
External alarm monitoring facility—By equipping your router with a telco-style external alarm 
monitoring facility, you can provide a more physical indication of router status. A visual alarm, 
however, can be reset only by resolving the problem that caused the alarm condition. 
For example, the same alarm signal that illuminates one of the three system alarm LEDs on the Cisco 
ASR1000-RP1 faceplate for a critical, major, or minor alarm condition is also sent to the DB-25 
connector by means of an associated alarm relay in the Cisco ASR1000-RP1.
An external alarm monitoring facility uses this signal to activate a visible alarm (such as a flashing 
light) or an audible alarm that immediately alerts site personnel to the existence of a router alarm 
condition. 
An external audible alarm can be reset by clearing the condition that caused the alarm or by pressing the 
Audible Cutoff (ACO) button on the Cisco ASR1000-RP1. An audible alarm can be sounded to 
immediately alert you of an alarm condition in the router. An audible alarm generated by the system 
continues to sound until you either clear the alarm condition itself or press the ACO button to silence the 
alarm. Pressing this button does not resolve the alarm condition. 
 lists the Cisco ASR 1000 Series Route Processors connectors and description.
Table 2-2
Cisco ASR 1000 Series Route Processor Connectors  
Label
Type
Description
ACO
Audible Cutoff button
When you press this button, an interrupt is 
generated informing software that the audible alarm 
relays will be disabled. This interrupt generates to 
both processors.
0
USB0 interface
Side-by-side USB connector used with memory 
sticks or smart cards for secure key distribution
1
USB1 interface
Side-by-side USB connector used with memory 
sticks or smart cards for secure key distribution
BITS 
RJ-45 connector
Indicates BITS timing reference.
MGMT 
ETHERNET
One RJ-45 jack for 
copper Ethernet 
Management Port
The route processor has an ENET port with a RJ-45 
connector to attach a management device or 
network for network management.