Cisco Systems OL-7396-01 Manual De Usuario

Descargar
Página de 934
9-5
ATM Switch Router Software Configuration Guide
OL-7396-01
Chapter 9
Configuring Resource Management
Configuring Global Resource Management
Configuring the Default QoS Objective Table
Resource management provides a table of default objective values for quality of service (QoS) for 
guaranteed service categories. These values—either metrics or attributes—are used as the criteria for 
connection setup requirements.
Note
Default objective values for QoS for guaranteed service categories can be configured for UNI 4.0 
signalling.
 lists the default values of the QoS objective table.
Each objective can have a defined or undefined value. If undefined, the objective is not considered in 
connection setup. The table should be configured with the same values for an entire network.
To configure the default QoS objective table, perform the following tasks in global configuration mode:
Example
The following example shows how to change the constant bit rate (CBR) maximum cell loss ratio 
objective for cell loss priority (CLP) = 0+1 to 10
-12
 cells per second:
Switch(config)# atm qos default cbr max-cell-loss-ratio clp1plus0 12
Table 9-3
Default QoS Objective Table Row Contents
Service
Category
Max Cell Transfer
Delay (clp01)
Peak-to-Peak Cell 
Delay Variation (clp01)
Cell Loss
Ratio (clp0)
Cell Loss Ratio
(clp0+1)
CBR
Undefined
Undefined
Undefined
Undefined
VBR-RT
Undefined
Undefined
Undefined
Undefined
VBR-NRT —
Undefined
Undefined
Command
Purpose
Step 1
Switch(config)# atm qos default {cbr vbr-rt
max-cell-transfer-delay {microseconds | any}
Selects the ATM QoS default CBR or VBR-RT 
maximum cell transfer delay.
Step 2
Switch(config)# atm qos default {cbr vbr-rt
peak-to-peak- cell-delay variation 
{microseconds | any}
Selects the ATM QoS default CBR or VBR-RT 
peak-to-peak cell delay variation.
Step 3
Switch(config)# atm qos default {cbr vbr-rt | 
vbr-nrtmax-cell-loss-ratio [clp0 | clp1plus0
{loss-ratio-exponent | any}
Selects the ATM QoS default CBR, VBR-RT, or 
VBR-NRT maximum cell loss ratio.