Delta Electronics DUP-B Manual De Usuario

Descargar
Página de 491
 
Chapter 3 Creating and Editing Screens 
Revision May, 2010 
 
 
3-37 
Example 1 
(PLC register) 
Example 2 
(HMI register) 
Word 
Control Register 
Address  Example  Address  Example 
General Control Status Register 2 (GCSR2) 
Dm+7 
D17 
$m+7 
$32 
Table 3-4-2 Status Block Designations 
General Control Status Register (GCSR) 
Bit 
Binary Display of Relative 
Position (x) 
Function 
0000 0000 0000 000x 
Screen Switch Status Flag 
1-2 
0000 0000 0000 0xx0 
Reserved 
0000 0000 0000 x000 
Clear Status of Alarm Buffer   
0000 0000 000x 0000 
Clear Status of Alarm Counter 
5-7 
0000 0000 xxx0 0000 
Reserved 
0000 000x 0000 0000 
User Security Level Flag (Level 1) 
0000 00x0 0000 0000 
User Security Level Flag (Level 2) 
10 
0000 0x00 0000 0000 
User Security Level Flag (Level 4) 
11-15 
xxxx x000 0000 0000 
Reserved 
 
Screen Switch Status Flag 
When HMI switches the screen, this flag is turned ON. After the screen switch is 
completed, this flag is turned OFF.   
 
Clear Status of Alarm Buffer 
When HMI clears the alarm buffer, this flag is turned ON. After this function is 
completed, this flag is turned OFF.   
 
Clear Status of Alarm Counter 
When HMI clears the alarm counter, this flag is turned ON. After this function is 
completed, this flag is turned OFF.   
 
User Security Level Flag 
Bits 8 to 10 hold the current user security level. 
Flag Control 
Level 
ON 
 
Binary Display 
Level 0 
 
Bit 8, Bit 9, Bit 10 
0000 0000 0000 0000 
Level 1 
Bit 8 
Bit 9, Bit 10 
0000 0001 0000 0000 
Level 2 
Bit 9 
Bit 8, Bit 10 
0000 0010 0000 0000 
Level 3 
Bit 8, Bit 9 
Bit 10 
0000 0011 0000 0000 
Level 4 
Bit 10 
Bit 8, Bit 9 
0000 0100 0000 0000 
Level 5 
Bit 8, Bit 10 
Bit 9 
0000 0101 0000 0000