3com NETBuilder SI Manual De Usuario

Descargar
Página de 212
190
A
PPENDIX
 E: P
ROVISIONING
 Y
OUR
 ISDN L
INE
AT&T 5ESS Custom Switch
To order ISDN service for an AT&T 5ESS custom switch, provide the 
telephone company with the information in Table 35.
CSD CHL
Any
TERMTYP
TYPEA or TYPEE
Display
No
CSD Limit
2
CA PREF
1
Table 35   Ordering ISDN Service for an AT&T 5ESS Custom Switch 
Required Information
Specification
Line type
ISDN line with point-to-point configuration
Line code
2B1Q (2B+D)
Interface type
S/T interface with NT1 (model 43x) or 
U interface (model 44x) and RJ-45 jack
Maximum terminals (MAXTERM)
1
Maximum B channels (MAXB CHNL)
2
Circuit-switched data (CSD)
2
Circuit-switched data channel (CSD 
CHL)
Any
Terminal type (TERMTYP)
A-Basic or E-Type (data only) Terminal
Display
No
Voice or data
Data
Call appearance preference
Idle
DN must be set as follows:
Parameter
Setting
B1
Circuit-switched data
B2
Circuit-switched data
D
Signaling only
ACT USR
Yes
TERMTYP
TYPEA or TYPEE
CSD Limit
2
CA PREF
1
Table 34   Ordering ISDN Service for an AT&T 5ESS Switch (continued)
Required Information