3com NETBuilder SI Manual De Usuario

Descargar
Página de 212
191
A point-to-point configuration on a SuperStack II bridge/router or 
boundary router is selected by setting the SPIDn1 and SPIDn2 parameters 
to none.
DMS 100 and National ISDN 1
To order ISDN service for a DMS 100 or National ISDN 1 switch, provide 
the telephone company with the information in Table 36.
Table 36   Ordering ISDN Service for a DMS 100 Switch
Required Information
Specification
Line type
DMS 100 or National ISDN 1 line
Line code
2B1Q (2B+D)
Interface type
S/T interface with NT1 (model 43x) or 
U interface (model 44x) and RJ-45 jack
Circuit-switched option
Yes
Bearer Restriction option
No packet mode data (NOPMD)
Protocol
Functional version 0 (PVC 0) for DMS 100
Functional version 2 (PVC 2) for National ISDN
SPID suffix
1 in North America only
Terminal endpoint identifier (TEI)
Dynamic
Ring
No
Key system (EKTS)
No
Voice or data
Data
DN must be set as follows:
Parameter
Setting
B1
Circuit-switched data
B2
Circuit-switched data
D
Signaling only
MAXTERM
1
MAXB CHNL
2
ACT USR
Y
CSD
2
CSD CHL
Any
Display
No
CSD Limit
2
CA PREF
1