Galil DMC-1400 Manual De Usuario

Descargar
Página de 235
DMC-1400  Series Command Reference MF 
● 139   
MF  
FUNCTION:  Forward Motion to Position 
DESCRIPTION: 
The MF command is a trippoint used to control the timing of events.   This command will 
hold up the execution of the following command until  the specified motor moves 
forward and crosses the position specified.   The units of the command are in quadrature 
counts.  The MF command can also be used when the encoder  is the master and not 
under servo control. 
ARGUMENTS:  MF n  where  
n is a signed integer in the range -2147483648 to 2147483647  decimal 
USAGE:     
While Moving 
Yes 
Default Value 
--- 
In a Program 
Yes 
Default Format 
--- 
Command Line 
Yes 
 
 
Can be Interrogated 
No 
 
 
Used as an Operand 
No 
 
 
Controller Usage 
ALL  
RELATED COMMANDS: 
Trippoint for after Relative Distance 
Reverse motion to position 
After Absolute Position 
EXAMPLES: 
#TEST  
Program B  
DP0  
Define zero  
JG 1000  
Jog mode (speed of 1000 counts/sec)  
BG   
Begin move  
MF 2000  
After passing the position 2000  
V1=_TP  
Assign V1 position  
MG "Position is", V1= ST 
Print Message Stop  
EN 
End of Program 
 
HINT:  The accuracy of the MF command is the number of counts that occur in 2  msec.  Multiply the 
speed by 2 msec to obtain the maximum error.  MF  tests for absolute position.  The MF command can 