Magnum 6K32T & 6K32TRC Managed Switch          Installation and User Guide 05/07) 
 
 
17
 
 
www  GarrettCom  com
.
.
SC or single mode SC or Long Reach SC ports.  For ports numbering, ports 1,3,5,7 are 
copper, ports 2 and 6 are fiber, ports 4 and 8 are not present.       
 
The four RJ-45 ports operate just like the 8-port copper module with auto-cross 
(MDIX) feature to eliminate the use of cross-over cable, and the two fiber ports operate 
at 100Mbps full-duplex (default). User mode control per port through the MNS software 
is also the same. 
On Magnum “4+2” Combo modules, there are four LED’s for each RJ-45 port, 
which indicate status the same as described for the 6K8-RJ45 in Section 2.2.3 above. The 
fiber port’s LEDs indicate status the same way as described for the SFF fiber modules in 
Section 2.2.2 above.  Color-coding on the panel of the module shows which LEDs 
belong to which port. 
 
The Magnum Combo six-port modules are also available with 4@ MTRJ 
100Mb mm SFF fiber and 2@10Mb fiber mm ST ports, and with 4@ RJ45 10/100 
copper and 2@10Mb fiber mm ST 
ports. The    
 4@ RJ-45 + 2@ 10 Mb ST 
 
operation of the SFF fiber 
and the RJ-45 half of the module is 
as described for those port types 
above.  For detailed information about 10Mb mm ST fiber half of the module, see 
Section 2.2.5. 
 
2.2.5 
 Four-Port  10 Mb  mm Fiber ST Modules 
 
 
 
 
 
 
The 4port @10Mb ST fiber modules behave the same as the 8@100Mb ST 
fiber modules except for the 10Mb speed. For port numbering, ports 1, 2, 5, 6 are present, 
ports 3, 4. 7, 8 are not present. The default setup on the 10Mb fiber module is half-
duplex, which allows the Magnum 6K32T & 6K32TRC Switch to connect to any 10Mb 
hub or media converter or almost any other device with a 10Mb fiber Ethernet port. User 
mode control per port through the MNS software is the same as the other 6K32T & 
1                    3                   5                 7
2                                           6
TX           RX
TX       LK     RX
LK
ACT
F/H
ACT
F/H
10/100
LK
F/H
ACT
 
2                                           6
T
 
LK 
 
R
ACT
F/H
TX           RX
LK
ACT
F/H
TX           RX
LK
ACT
F/H
TX           RX
LK
ACT
F/H
1                                          5