CHAPTER 10: Using Management and Serial Control Cards
123
10.4.2 D
ISPLAY
F
LASH
ROM S
TATUS
When you choose option 2 from the main menu, you will be prompted to enter a channel address. Enter a
remote address or leave the field blank for the local channel (that is, for the Management Card itself). The
firmware type and current firmware-revision level of the selected Card—which can be any type of ServSwitch
Multi Card—will be displayed as shown below.
Display Flash ROM Status
Channel address [0-H]:
Pos Flash Type FW Rev
--- ---------- ------
1  XPIQ       -NA-
2  Available
3  Available
4  Available
5  Available
6  Available
7  Available
8  Available
9  Available
The “Pos” column shows which “slot” in the Card’s memory a firmware program is stored in: Management
Cards have nine of these, numbered 1 through 9; all other Cards have only one, numbered 1. The “Flash Type”
indicates what type of Card the program is designed for—see Note 2 on the previous page for explanations of
what these abbreviations mean—or says “Available” if the slot is empty. The “FW Rev” column indicates the
revision level of the program, or says “–NA–” if (as is the case with the Management Card/XPIQ firmware in
slot one) the firmware can’t be transmitted to any other Card.