cOnnectIOn tO tHe mAInS netWORk
Connection must always be carried out via 
an appropriately grounded safety outlet with 
residual-current-operated circuit-breaker.
Before connecting the unit to the mains supply, ensure that 
the line voltage matches that specified on the unit’s rating 
plate.
s t ar tup
4.4 
cleAnInG PReSeRVInG AGent WHen 
StARtInG-uP OF OPeRAtIOn InItIAlly
1.  Immerse the suction system into a container filled with a 
suitable cleaning agent (recommendation: water).
2.  Switch on unit.
3.  Turn the pressure regulating knob (1) to the right until 
the stop is reached.
4.  Open relief valve (2)
 
valve position   
   (circulation)
5.  Wait until cleaning agent is emitted from the return hose.
6.  Turn the pressure regulating knob (1) back approx. one 
rotation.
7.  Close relief valve (2)
 
valve position   
   (spraying), pressure is rising up inside 
the high pressure hose (visible at pressure gauge)
8.  Point the tip of the spray gun into an open collecting con-
tainer and pull the trigger guard at the spray gun.
9.  The pressure is increased by turning the pressure regulat-
ing knob (1) to the right. Set approx. 10 MPa at the pres-
sure gauge.
10.  Spray the cleaning agent out of the unit for approx. 
1 - 2 min. (~5 litres) into the open collecting container.
4.6 
tAkInG tHe unIt IntO OPeRAtIOn WItH 
cOAtInG mAteRIAl
1.  Immerse the suction system into a container filled with 
coating material.
2.  Press inlet valve pusher (4) several times to release pos-
sibly clogged inlet valve
3.  Open relief valve (2)
 
valve position   
   (circulation)
4.  Switch on unit.
5.  Turn the pressure regulating knob (1) to the right until 
the stop is reached.
 
When the noise of the valves changes, the unit is bled and 
takes in coating material.
6.  If coating material exits from the return hose, turn the 
pressure regulating knob (1) back approx. 1 rotation.
7.  Close relief valve (2)
 
valve position   
   (spraying), pressure is rising up inside 
the high pressure hose (visible at pressure gauge)
8.  Pull of the spray gun and spray into an open collecting 
container in order to remove the remaining cleaning 
agent from the unit. When coating materials exits from 
the tip, close the spray gun.
9.  Pull of the spray gun and adjust the spraying pressure by 
turning the pressure regulating knob (1).
10.  The unit is ready to spray.
4.5 
VentIlAte unIt (HydRAulIc SyStem) IF tHe 
SOund OF Inlet VAlVe IS nOt AudIBle
1.  Switch on the unit.
2.  Turn pressure regulating knob (1) three revolutions to 
the left.
3.  Open relief valve (2)
 
valve position   
   (circulation)
 
The hydraulic system is ventilated. Leave the unit on for 
two or three minutes.
4.  Then turn pressure regulating knob (1) to the right until 
stop.
5.  Press inlet valve pusher (4).
 
Sound of the inlet valve is audible.
6.  If not, repeat points 2 and 4
1
2
3