r epa Irs  at  the  un It
10.4 
PReSSuRe cOntROl VAlVe
Only have the pressure control valve (1) re-
placed by the customer service.
The max. operating pressure has to be reset 
by the customer service.
10.5 
RelIeF VAlVe
Replace a fault relief valve (1) as a single unit.
Only the O-ring (2) may be replaced as a single part
10.6 
RePlAcInG tHe dIAPHRAGm
Switch the unit off.
Before all repair work: Unplug the power 
plug from the outlet.
1.  Screw the trigger housing with inlet valve out of the paint 
section as described in Section 10.2 Inlet valve, Items 1 to 
3. (disassembling of hexagon nuts will become easier)
2.  Turn back the pressure control valve, rotary knob com-
pletely (anti-clockwise).
 
(Note: If the unit is still warm, open the oil screw plug (6) 
briefly in order to compensate the pressure and close it 
again.)
3.  Use a 19 mm wrench to screw the hexagonal bolt (Item 1) 
out of the flange ring (2).
4.  Remove the paint section (3).
5.  Remove the insert (4) and the diaphragm (5).
6.  The diaphragm can only be used once. Always replace the 
diaphragm.