FlavorFusion Installation Manual
Publication Number: 621057601INS
- 4 -
© 2005-2006, IMI Cornelius Inc.
NOTE:  See applicable Flow Diagram (see FIGURE 8) or Decal on the lower front of the unit for the 
location of syrup and water connections.
6.
Clean the hopper interior (see CLEANING INSTRUCTIONS in Owner’s Manual).
7.
Connect the unit power cord to a 120 volt, 60 cycle, 3–wire grounded receptacle. For 220-240 Volt 
International Units, a 3-wire power cord is provided. An adapter plug for the particular country will 
need to be provided by the Installer.
A
DJUST
 C
ARBONATOR
 CO
2
 R
EGULATOR
 
AND
 T
URN
 W
ATER
 I
NLET
 S
UPPLY
 
L
INE
 ON 
CAUTION: Before connecting the CO
2
 regulator assembly to a CO
2
 cylinder, turn the regulator 
adjusting screw to the left (counterclockwise) until all tension is relieved from the adjusting screw 
spring.
1.
Open (counterclockwise) CO
cylinder valve slightly to allow lines to slowly fill with gas, then open 
the valve fully to back-seat the valve. (Back-seating the valve prevents leakage around the valve 
shaft). 
2.
The carbonator CO
regulator is fixed at a nominal 75 psi.
3.
Open one of the post-mix dispensing valves to exhaust trapped air inside the carbonator tank.
4.
Open the water inlet supply line shutoff valve.
U
NIT
 O
PERATION
WARNING: The unit must be electrically grounded to avoid possible fatal electrical shock or serious 
injury to the operator. The unit power cord is equipped with a three-prong plug. If a three-hole 
(grounded) electrical outlet is not available, use an approved method to ground the unit.
CAUTION:  Never operate the carbonator pump with the water inlet supply line shutoff valve 
closed. “Dry running” the water pump will burn out the pump. A pump damaged in this manner is 
not covered by warranty.
1.
Connect electrical power to the Unit. 
2.
Locate the switch on the junction box of the carbonator pump, and turn it ON. The water pump will 
start and fill the carbonator tank with carbonated water. The water pump will stop when the 
carbonator tank is full.
3.
Check for water and CO
2
 leaks, and tighten any loose connections
4.
Dispense several drinks until the carbonator pump cycles on. The refill time should be about 5-7 
seconds. 
5.
If the carbonator pump appears to be short-cycling, meaning a refill time of 1-2 seconds, refer to the 
Troubleshooting section.