% BYPASS
 
This function allows adjustment of the amount of 
water that bypasses the grounds. The number signi-
fi es the percentage of the brew volume which does 
not fl ow over the coffee grounds.
Modifying recipes - bypass percentages:
Range: 0% to 90% for all three batch sizes
NOTE: If the brewer is already in the % BYPASS screen, 
it is not necessary to follow steps 1 through 6 in this 
section, but proceed directly to step 7.
1.  Press and hold upper right hidden switch until 
the display reads UNITS. Release the switch, then 
press and release switch until the display reads 
REVIEW RECIPES.
2. Press YES to proceed. The display should now 
read NO-NAME LEFT, along with MODIFY, SHOW 
and NEXT.
3. Press 
and 
release 
NEXT to advance to the desired 
coffee name to be modifi ed.
P2292
4.  Press and release MODIFY.  The display should 
read BREW OZ. 
5. Press 
and 
release 
DONE. The display should read 
3 BATCHES DONE?.
6.  Press and release YES. The display should now 
read % BYPASS, and a batch light will be blinking. 
Press and release the batch size to be modifi ed.
7. Using 
(-) and (+) set the amount of bypass water 
(percentage) to be dispensed around the grounds 
for that particular batch size.
8. When 
fi nished, press another batch size and repeat 
step 7 for each batch to be modifi ed.
9.    When fi nished setting all batch sizes, press DONE
The display should read 3 BATCHES DONE? 
10. If they are not correct, press and release NO to 
return to the % BYPASS setup screen.
11.  If the 3 batch sizes are correct, press YES. This will 
advance to SET PULSE BREW. Another alternative 
is to press either ON/OFF switch located on the 
front switch panel to exit the % BYPASS setup 
and return to the MAIN SCREEN.