Furuno FCR-28x9 Manual De Usuario

Descargar
Página de 423
3.  TARGET TRACKING (TT)
3-21
3.16
TT Alerts
There are nine situations that cause the TT to trigger visual and audio alerts. To ac-
knowledge the audio alerts, push the ALARM ACK key, or click the [Alert] box.
Alert
No.
Message
Category
Description
520
TT System Error
Warning
TT system is inoperative. Check-
ing heading sensor, antenna.
521
TT New Target
Warning
Tracked target entered the ac-
quisition zone.
522
TT Auto ACQ 95%
Caution
The capacity for auto acquisition 
has reached 95%.
523
TT Auto ACQ 100%
Warning
The capacity for auto acquisition 
has reached 100% and no more 
target acquisition is possible. 
Cancel tracking on unnecessary 
targets.
524
TT Man ACQ 95%
Caution
The capacity for manual acquisi-
tion has reached 95%.
525
TT Man ACQ 100%
Warning
The capacity for manual acquisi-
tion has reached 100% and no 
more target acquisition is possi-
ble. Cancel tracking on unneces-
sary targets.
526
TT CPA/TCPA
Alarm
Tracked target on collision 
course. Take evasive action.
527
TT Lost
Warning
Tracked target lost. Check tar-
get.
528
REF Target Lost
Warning
Tracked target used for speed in-
put is lost. To continue using ref-
erence target for speed input, 
select another tracked target.