CHAPTER 4: Installing Your Tape Drive
81-85002-01
March 2004
4-23
If the SDLT drive is one of several devices connected to the SCSI bus, 
and it is the last device connected to the SCSI bus, attach the SCSI 
terminator to one of the connectors on the back of the drive.
4.
Align the appropriate SCSI cable to its matching connector on the drive. 
Carefully connect the cable, to avoid bending or damaging the connector pins. 
Check the SCSI cable and termination connections and ensure that they are 
attached correctly and seated firmly.
5.
Snap the wire cable clamps into place to secure the cables.
AC Power Cable
An AC power cord is supplied with each tabletop unit. Carefully inspect the power 
cord and ensure that the cord is the appropriate cord for your country or region 
based on the criteria below.
The AC power cord used with the tabletop unit must meet the following criteria:
The power cord should be a minimum of 18/3 AWG, 60°C, type SJT or SVT.
UL and CSA certified cordage rated for use at 250 V AC with a current rating 
that is at least 125% of the current rating of the product.
The AC plug must be terminated in a grounding-type male plug designed for 
use in your country or region. It must also have marks showing certification 
by an agency acceptable in your country or region.
The tabletop unit cord connector must be an IEC type CEE-22 female 
connector.
The cord must be no longer than 4.5 meters (14.5 feet).
The cord must be FCC compliant with emissions specifications.
 shows the AC power cord plug-end types for 115 V AC 
and 220/240 V AC usage.
W
ARNING
Do not attempt to modify or use a tabletop 100–115 
V AC power cord for 220–240 V AC input power. 
Modifying the power cord in any way can cause 
personal injury and severe equipment damage.