3com 7000 Manual Suplementario
![3com](https://files.manualsbrain.com/attachments/960452ff43b9899cbcffced60c87abf956e7967a/common/fit/150/50/f6ac125d7af2cf40fec58935fa6d4bf71457a57efe50bee91208a434f325/brand_logo.jpeg)
228
C
HAPTER
7: C
ONFIGURING
V
IRTUAL
C
HANNELS
Add VP Tunnel to Port
Adds a VP tunnel to a port of the CoreBuilder 7000 family ATM switch.
VP tunnels can only be configured for a port if VP tunneling is enabled for
the port. The VP tunnel is associated with a specific VPI value in the range
0:7 and a VP tunnel type: point-to-point (P2P) or point-to-multiple (P2M).
For more information, see “VP Tunneling” on page 5-101.
VP tunnels can only be configured for a port if VP tunneling is enabled for
the port. The VP tunnel is associated with a specific VPI value in the range
0:7 and a VP tunnel type: point-to-point (P2P) or point-to-multiple (P2M).
For more information, see “VP Tunneling” on page 5-101.
Only one VP tunnel of type P2M can be defined per port. If you try to
define a second VP tunnel of type P2M (with a different VPI) the first will
be removed.
define a second VP tunnel of type P2M (with a different VPI) the first will
be removed.
Command Actions
Command Result
Enter the menu sequence:
(1) SYS: Platform config
(1) SET: Switch setup
(9) VPT: VP Tunneling Setup
(3) TUN: Tunnels Setup
(2) ETN: Enable Tunnel on Port
Enter a parameter at the prompt
Parameter
Format or Range
Port Number
slot.port
VPI Value
0 through 7
Tunnel Type
0 – P2P
1 – P2M
1 – P2M
Direct access sequence:
1 1 9 3 2
[parameters]
System action taken:
A VP tunnel is added to a port. The change takes place
immediately.
immediately.
System message display: