Bunn GMB-PS Guía Del Usuario

Descargar
Página de 24
Page 16
ON
OFF
ST
AR
T
B
U
N
N
90 psig max operating pressure
S
trainer/Flow Control # 24222.0222
R
epl. Flow W
asher #20526.0222 )
(Repl. Screen #23721.0000)
.222 gpm FLOW
SERVICE (cont.)
ON/OFF SWITCH
Location:
The ON/OFF switch is located on the left front of
the hood.
Test Procedure:
1. Disconnect the brewer from the power source.
2. Viewing  the  switch  from  the  back  remove  the
white wire or red wire from the upper terminal and
the black wire from the center terminal.
3. With  a  voltmeter,  check  the  voltage  across  the
white wire or red wire and the black wire. Connect
the  brewer  to  the  power  source.  The  indication
must be:
a) 120 volts ac for two wire 120 volt models, three
wire 120/208 or 120/240 volt models.
b) 200 to 240 volts ac for two wire 200 or 240 volt
models.
4. Disconnect the brewer from the power source.
If voltage is present as described, reconnect the white
or red wire and proceed to #5.
If  voltage  is  not  present  as  described,  refer  to  the
Wiring  Diagrams  and  check  the  brewer  wiring  har-
ness.
5. With the black wire removed, remove the white/
red wire from the lower terminal.
6. Check for continuity across the center and lower
terminal  with  the  switch  in  the  "ON"  position.
Continuity must not be present when the switch is
in the "OFF" position.
If  continuity  is  present  as  described,  reconnect  the
black wire to the center terminal and the white/red to
the lower terminal.
If continuity is not present as described, replace the
switch.
Removal and Replacement:
1. Remove the wires from the switch terminals.
2. Compress  the  clips  inside  the  hood  and  gently
push the switch through the opening.
3. Push the new switch into the opening and spread
the clips to hold switch in the hood.
4. Refer to Fig. 7 when reconnecting the wires.
P2267
P1173
27479 121500
FIG. 6 ON/OFF SWITCH
FIG. 7 ON/OFF SWITCH TERMINALS
WHI to Power Cord (120V
Model 15)
WHI  to  Terminal  Block
(White  Insert  on  120V,
120/208V  or  120/240V
Models)
RED  to  Terminal  Block
(Red Insert on 200V - 240V
Models)
BLK to Power Cord
(120V Model 15)
BLK to Terminal Block
(Black Insert on 120V,
120/208,  120/240,
200 & 240V Models)
WHI/RED to Timer TL1