Procedure to adjust the flow rate setting:
1.  Press and hold the upper right hidden switch until 
the display reads UNITS. Release the switch, then 
press and release switch until the display reads  
BYPAS OZ/M. The number represents what the 
brewer thinks is the flow rate of the bypass valve 
in ounces per minute.
2.  If the actual flow rate of the bypass valve is known, 
but is different than the number on the display, 
use the (-) and (+) to enter the correct flow rate 
in ounces per minute.
Procedure to adjust the flow rate setting:
1.  Press and hold the upper right hidden switch until 
the display reads UNITS. Release the switch, then 
press and release switch until the display reads 
SPRAY OZ/M. The number represents what the 
brewer thinks is the flow rate of the sprayhead 
valve in ounces per minute.
2.  If the actual flow rate of the sprayhead valve is 
known, but is different than the number on the 
display, use the (-) and (+) to enter the correct 
flow rate in ounces per minute.
3.  When finished, press and release DONE. This saves 
the new setting and advances to the next function 
screen, BYPASS OZ/M. Another alternative is to 
press the ON/OFF switch located on the switch 
panel to exit SPRAY OZ/M function and return to 
the MAIN SCREEN.
BYPASS OZ/M
 
This function allows the operator to view or to enter 
the actual flow rate coming out of the bypass nozzle.  
This is NOT used to change the actual flow rate, but to 
tell the internal controller how fast the water is flowing. 
The unit of measure is ounces per minute.
PROGRAMMING THE BREWER (cont.)
SPRAY OZ/M (cont.)
3.  When finished, press and release DONE. This saves 
the new setting and advances to the next function 
screen, CALIBRATE FLOW. Another alternative is 
to press the ON/OFF switch located on the front 
switch panel to exit the BYPASS OZ/M function 
and return to the MAIN SCREEN.
CALIBRATE FLOW
 
This function allows the operator to enter the actual 
flow rate of the sprayhead and the bypass by dispens-
ing both separately for one minute. The volumes are 
then entered in ounces per minute. (Oz/M)
Procedures to calibrate the sprayhead flow rate:
1.  Place a container, accurately graduated in ounces, 
and with a minimum capacity of 60 ounces, beneath 
the funnel on the brewer.
2.  Press and hold the upper right hidden switch until 
the display reads UNITS. Release the switch, then 
press and release switch until the display reads  
CALIBRATE FLOW.
3.  Press and release YES to advance to the SPRAY-
HEAD CAL? function screen. (Pressing NO in the 
CALIBRATE FLOW screen will advance to the next 
function screen, BREW COUNTERS).
4.  Press and release the YES pad. The display should 
read CONTAINER READY? If the container is under 
the funnel, press YES. The display should read 
CALIBRATE SPRAY .. PRESS BREW TO START.
5.  Press and release the BREW switch. The display 
should read CALIBRATE SPRAY .. 60 SEC TO FIN-
ISH. The 60 second timer on the display will count 
down to zero. When the counter reaches zero, the 
display will change to ENTER OZ.,  along with a 
number measured in ounces per minute.
6.  Measure  the  amount  of  water  in  the  container 
and using the (-) or (+), adjust the amount on the 
display to match the amount in the container. Then 
press DONE.
7.  The display should now read NEW SPRAY FLOW
along with the correct flow rate of the sprayhead 
in  ounces  per  minute.  After  about  5  seconds, 
the display will return to the CALIBRATE FLOW 
screen.
8.  To exit the CALIBRATE FLOW program, press NO 
to advance to the next function screen, or press  
the  ON/OFF  switch  located  on  the  front  switch 
panel to exit the CALIBRATE FLOW function and 
return to the MAIN SCREEN.
P2721
SPRAY OZ/M: XXX
  (-) 
DONE 
(+)
P2721
BYPAS OZ/M: XXX
  (-) 
DONE 
(+)