This function allows the operator to track the num-
ber of brew cycles completed. There is one resettable 
counter, and one life counter that is not resettable.
EXIT TO
NEXT FUNCTION
SCREEN
XXXX
            NEXT   RESET
XXXX
NEXT
BREW COUNTERS?
NO                      YES
Procedures to view/reset the brew counters:
1.  Press and hold the upper right hidden switch until 
the display reads UNITS. Release the switch, then 
press and release switch until the display reads 
BREW COUNTERS.
2.  Pressing NO in this screen will advance to the next 
function.  Press YES to view the first brew counter. 
This number represents the brew cycles initiated 
since that counter was last reset.
3.  To  reset  the  resettable  counter  to  zero  press 
and release RESET when viewing that particular 
counter's screen.
P2448
Procedure to set funnel detect:
1.  Press and hold the upper right hidden switch until 
the display reads UNITS. Release the switch, then 
press and release switch until the display reads 
FUNNEL DETECT.
2.  NO or YES should be flashing to indicate the cur-
rent setting.
3.  Select YES to prevent brewing if a Smart Funnel is 
not correctly situated in the rails. If this function is 
activated and a brew cycle is attempted with the 
funnel not properly situated, the display will read, 
FUNNEL NOT IN PLACE, until one is in place.
4.  Select NO to allow brewing without a Smart Fun-
nel in place. This is selected when brewing with a 
funnel other than a Smart Funnel (a regular brew 
funnel).
5.  When finished, press and release DONE. This will 
retain the changes, exit this function screen and 
advance to the next. Another alternative is to press 
the  ON/OFF  switch  located  on  the  front  switch 
panel to exit the FUNNEL DETECT and return to 
the MAIN SCREEN.
PROGRAMMING THE BREWER (cont.)
7.  Measure the amount of water in the container, and 
using (-) or (+), adjust the amount on the display 
to match the amount in the container. Then press 
DONE.
8.  The display should now read NEW BYPASS FLOW
along with the correct flow rate of the bypass in 
ounces per minute. After about 5 seconds, the dis-
play will return to the CALIBRATE FLOW screen.
9.  To exit the CALIBRATE FLOW function, press and 
release NO to advance to the next function screen, 
or press the ON/OFF switch located on the front 
switch panel to exit the CALIBRATE FLOW function 
and return to the MAIN SCREEN.
CALIBRATE FLOW (cont.)
4.  To advance to the other counter, press and release 
NEXT. This will advance to total brews (non-reset-
table).
5.  When finished, press NEXT until the display reads 
BREW COUNTERS. Press and release NO to ad-
vance to the next function screen, or press the 
ON/OFF switch located on the front switch panel 
to exit the BREW COUNTERS function and return 
to the MAIN SCREEN.
FUNNEL DETECT (optional)
 
This function allows the operator to prevent the 
start of a brew cycle if a Smart Funnel is not positioned 
correctly in the funnel rails.
P2721
FUNNEL DETECT ?
  NO 
DONE 
YES