Procedures to calibrate the bypass flow rate:
1.  Place a container, accurately graduated in ounces, 
and with a minimum capacity of 60 ounces, below 
the funnel on the brewer.
2.  Press and hold the upper right hidden switch until 
the display reads UNITS.Release the switch, then 
press and release switch until the display reads 
CALIBRATE FLOW.
3.  Press and release YES to advance to the SPRAY-
HEAD CAL? function screen. (Pressing NO in the 
CALIBRATE FLOW screen will advance to the next 
function screen, BREW COUNTERS).
4.  Press and release NO to advance to the BYPASS 
CALIBRATION screen.
ENTER  OZ   XX.X
(-)      DONE       (+)
NEW BYPAS FLOW
XX.X OZ/M
EXIT TO THE
NEXT FUNCTION
SCREEN
COUNTS DOWN
TO ZERO
BREW PRESSED
AFTER 1 MINUTE
CALIBRATE FLOW?
NO                     YES
CONTAINER RDY?
NO                     YES
CALIBRATE BYPASS
PRESS BREW START
CALIBRATE BYPASS
60 SEC TO FINISH
BYPASS CAL?
NO                     YES
SPRAYHEAD CAL?
NO                     YES
P2314
PROGRAMMING THE BREWER (cont.)
NEW SPRAY FLOW
XX.X OZ/M
ENTER OZ  XX.X
(-)        DONE        (+)
CALIBRATE FLOW?
NO                     YES
SPRAYHEAD CAL?
NO                     YES
CONTAINER RDY?
QUIT                   YES
CALIBRATE SPRAY
PRESSBREWSTART
CALIBRATE SPRAY
60 SEC TO FINISH
COUNTS DOWN
TO ZERO
AFTER 1 MINUTE
BREW PRESSED
EXIT TO THE
NEXT FUNCTION
SCREEN
P2307
CALIBRATE FLOW (cont.)
5.  Press  and  release  the  YES  switch.  The  display 
should read CONTAINER READY? If the container 
is under the funnel, press YES. The display should 
read  CALIBRATE  BYPASS  ..  PRESS  BREW  TO 
START.
6.  Press and release the BREW switch. The display 
should read CALIBRATE BYPASS .. 60 SEC TO 
FINISH. The 60 second timer on the display will 
count down to zero. When the counter reaches 
zero, the display will change to ENTER OZ., along 
with a number measured in ounces per minute.
34025.2 071105