Bunn single sh brewwise dbc Guía De Operación

Descargar
Página de 53
Page 35
SERVICE TOOLS
 
This function allows the testing of individual com-
ponents and the ability to check switches for proper 
function. This function also tests the Soft Heat server's 
status on the brewer (in place or removed), and the 
funnel  sensor  coil's  frequency  (diagnostic  tool  for 
troubleshooting purposes only).
EXIT TO
NEXT FUNCTION
SCREEN
EXIT TO
NEXT FUNCTION
SCREEN
PRESS AND RELEASE
® SYMBOL
PRESS AND RELEASE
® SYMBOL
PRESS AND RELEASE
® SYMBOL
NEXT COMPONENT
TO BE TESTED
TEST OUTPUTS?
NO                     YES
TEST SWITCHES?
NO                     YES
BREW VALVE
ON      NEXT      OFF
SERVER REMOVED
              IN PLACE
125.0 KHZ.    4
4     125.0 KHZ.        
NOTHING PRESSED
TEST FREQUENCY?
NO                     YES
TEST SERVERS?
NO                     YES
SERVICE TOOLS?
NO                     YES
P2449
Procedures to set server detect:
1.  Press and hold the upper right hidden switch until 
the display reads UNITS. Release the switch, then 
press and release switch until the display reads 
SERVER DETECT.
2.  The  NO  or  YES  flashes  to  indicate  the  current 
selection.
3.  Select  YES  to  prevent  brewing  if  the  Soft  Heat 
server is not correctly positioned on the brewer 
beneath the funnel.  
NOTE: If  YES is selected and a brew cycle is attempted 
with a server not properly placed, the display will read 
SERVER NOT IN PLACE.
4.  Select NO to allow brewing without a Soft Heat 
server in place. This is selected when brewing into 
a container other than a Soft Heat Server.
5.  When finished, press and release DONE. This will 
save the new setting, exit the function screen and 
advance to the next. Another alternative is to press 
the ON/OFF switch located on the front switch panel 
to exit the SERVER DETECT function and return 
to the MAIN SCREEN.
SERVER DETECT
 
This function allows the operator to prevent the start 
of a brew cycle if a Soft Heat server is not positioned 
correctly on the brewer.
PROGRAMMING THE BREWER (cont.)
P2721
SEVER DETECT ?
  NO 
DONE 
YES
34025.2 071105