Honeywell TH5110D Guía De Instalación

Descargar
Página de 24
3
Wiring conventional systems
Shaded areas below apply only to 
TH5320U/TH5220D
 or as otherwise noted.
1H/1C System  
(1 transformer)
Rc 
Power 
[1]
[R+Rc joined by jumper]
Compressor contactor
24VAC common 
[3]
Heat relay
Fan relay
Heat-only  
System
Rc 
Power 
[1]
[R+Rc joined by jumper]
24VAC common 
[3]
Heat relay
Heat-only  
System  
(Series 20)
 
[5]
Rc 
[R+Rc joined by jumper]
Series 20 valve terminal “R” 
[1]
Series 20 valve terminal “W”
24VAC common 
[3]
Series 20 valve terminal “B”
Heat-only  
System  
(normally open zone valve)
 
[5]
Rc 
[R+Rc joined by jumper]
Power 
[1]
Normally open zone valve
24VAC common 
[3]
1H/1C System  
(2 transformers)
Rc 
Power (cooling transformer) 
[1, 2]
Power (heating transformer) 
[1, 2]
Compressor contactor
24VAC common 
[3, 4]
Heat relay
Fan relay
Heat-only System  
with Fan
Rc 
Power 
[1]
[R+Rc joined by jumper]
24VAC common 
[3]
Heat relay
Fan relay
Cool-only System
Rc 
Power 
[1]
[R+Rc joined by jumper]
Compressor contactor
24VAC common 
[3]
Fan relay
2H/2C System  
(1 transformer)
 
[6]
Rc 
Power 
[1]
[R+Rc joined by jumper]
Compressor contactor (stage 1)
24VAC common 
[3]
Heat relay (stage 1)
Fan relay
W2 
Heat relay (stage 2)
Y2 
Compressor contactor (stage 2)
2H/2C System  
(2 transformers)
 
[6]
Rc 
Power (cooling transformer) 
[1, 2]
Power (heating transformer) 
[1, 2]
Compressor contactor (stage 1)
24VAC common 
[3, 4]
Heat relay (stage 1)
Fan relay
W2 
Heat relay (stage 2)
Y2 
Compressor contactor (stage 2)
Rc
Y
W
G
R
C
M29372
Rc
W
R
C
M29373
Rc
Y
W
R
C
M29374
Rc
Y R
C
M29375
Rc
Y
W
G
R
C
M29376
Rc
W
G
R
C
M29377
Rc
Y
G
R
C
M29378
Rc
Y
W
G
W2
Y2
R
C
M29379
Rc
Y
W
G
W2
Y2
R
C
M29380
NOTES
Wire specifications: 
Use 18- to 22-gauge thermostat wire.  
Shielded cable is not required.
[1]
  Power supply. Provide disconnect means 
and overload protection as required.
[2]
  Remove jumper for 2-transformer systems.
[3]
  Optional 24VAC common connection.
[4]
  Common connection must come from cool-
ing transformer.
[5]
  In Installer Setup, set system type to  
Heat Only.
[6]
  In Installer Setup, set system type to 
2Heat/2Cool Conventional.
[7]
  In Installer Setup, set changeover valve to 
O or B.
[8]
  In Installer Setup, set system type to 
2Heat/1Cool Heat Pump.
[9]
  In Installer Setup, set system type to 
2Heat/2Cool Heat Pump.
[10
]  In Installer Setup, set system type to 
3Heat/2Cool Heat Pump.
[11
]  L terminal sends a continuous output when 
thermostat is set to Em. Heat. Connect 
to Honeywell zoning panels to switch the 
panel to Emergency Heat.