Follow the procedure below to configure 
the thermostat to match the installed 
heating/cooling system, and customize 
feature operation as desired.
1.  To begin, press and hold the 
s
 
and FAN
 
buttons until the display 
changes.
2.  Press 
s
 or 
t
 to change settings.
3.  Press NEXT to advance to next 
function.
4.  Press DONE to exit and save 
settings.
Installer setup
Setup function 
Settings & options (factory default in bold)
Shaded areas below apply only to 
TH5320U/TH5220D
 or as otherwise noted.
 
1
 
System type
1 heat/1 cool conventional
1 heat/1 cool heat pump (no aux. heat)
Heat only — 2-wire systems, 3-wire zone valves (Series 20), 
and normally open zone valves
Heat only with fan
Cool only
2 heat/1 cool heat pump (with aux. heat)
2 heat/2 cool conventional
2 heat/1 cool conventional
1 heat/2 cool conventional
2 heat/2 cool heat pump (no aux. heat) - 
TH5320U
 only
10  3 heat/2 cool heat pump (with aux. heat) - 
TH5320U
 only
 
2
 
Changeover valve 
(O/B terminal)
Changeover valve (O/B terminal energized in cooling)
Changeover valve (O/B terminal energized in heating)
 
3
 
Fan control 
(heating)
Gas or oil furnace — equipment controls fan in heating
Electric furnace — thermostat controls fan in heating
 
5
 
Stage 1 heat cycle  
rate 
(CPH: cycles/hour)*
For gas or oil furnaces of less than 90% efficiency
For steam or gravity systems
For hot water systems & furnaces of over 90% efficiency
For electric furnaces
 
6
 
Stage 2 heat cycle  
rate/Auxiliary heat  
cycle rate (CPH)*
For gas or oil furnaces of less than 90% efficiency
For steam or gravity systems
For hot water systems & furnaces of over 90% efficiency
For electric furnaces
 
7
 
Auxiliary heat  
cycle rate (CPH)*
  
Only 
TH5320U
 
for 3H/2C Heat 
Pumps
For gas or oil furnaces of less than 90% efficiency
For steam or gravity systems
For hot water systems & furnaces of over 90% efficiency
For electric furnaces
Function 
number
Setting
1
0
Done
Next
M29387
*[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]