Honeywell TH5110D Guía De Instalación
5
1
0
Done
Next
M29387
Follow the procedure below to configure
the thermostat to match the installed
heating/cooling system, and customize
feature operation as desired.
1. To begin, press and hold the
1. To begin, press and hold the
s
and FAN
buttons until the display
changes.
2. Press
s
or
t
to change settings.
3. Press NEXT to advance to next
function.
4. Press DONE to exit and save
settings.
Installer setup
Setup function
Settings & options (factory default in bold)
Shaded areas below apply only to
TH5320U/TH5220D
or as otherwise noted.
1
System type
0
1 heat/1 cool conventional
1
1 heat/1 cool heat pump (no aux. heat)
2
Heat only — 2-wire systems, 3-wire zone valves (Series 20),
and normally open zone valves
3
Heat only with fan
4
Cool only
5
2 heat/1 cool heat pump (with aux. heat)
6
2 heat/2 cool conventional
7
2 heat/1 cool conventional
8
1 heat/2 cool conventional
9
2 heat/2 cool heat pump (no aux. heat) -
TH5320U
only
10 3 heat/2 cool heat pump (with aux. heat) -
TH5320U
only
2
Changeover valve
(O/B terminal)
0
Changeover valve (O/B terminal energized in cooling)
1
Changeover valve (O/B terminal energized in heating)
3
Fan control
(heating)
0
Gas or oil furnace — equipment controls fan in heating
1
Electric furnace — thermostat controls fan in heating
5
Stage 1 heat cycle
rate
(CPH: cycles/hour)*
5
For gas or oil furnaces of less than 90% efficiency
1
For steam or gravity systems
3
For hot water systems & furnaces of over 90% efficiency
9
For electric furnaces
6
Stage 2 heat cycle
rate/Auxiliary heat
cycle rate (CPH)*
5
For gas or oil furnaces of less than 90% efficiency
1
For steam or gravity systems
3
For hot water systems & furnaces of over 90% efficiency
9
For electric furnaces
7
Auxiliary heat
cycle rate (CPH)*
Only
TH5320U
for 3H/2C Heat
Pumps
5
For gas or oil furnaces of less than 90% efficiency
1
For steam or gravity systems
3
For hot water systems & furnaces of over 90% efficiency
9
For electric furnaces
Function
number
Setting
1
0
Done
Next
M29387
*[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]