Honeywell TH5110D Guía De Instalación

Descargar
Página de 24
4
Thermostat mounting
1.  Push excess wire back into the 
wall opening.
2.  Plug wall opening with non-
flammable insulation.
3.  Align the 4 tabs on the wallplate 
with corresponding slots on the 
back of the thermostat. 
4.  Push gently until the thermostat 
snaps in place.
M29386
Rc
Y
G
R
C
M29381
1H/1C Heat Pump  
System
Rc 
Power 
[1]
[R+Rc joined by jumper]
Compressor contactor
24VAC common 
[3]
O/B 
Changeover valve 
[7]
Fan relay
2H/1C Heat Pump  
System (TH5220D only) 
[8]
Rc 
Power 
[1]
[R+Rc joined by jumper]
Compressor contactor
24VAC common 
[3]
O/B 
Changeover valve 
[7]
Fan relay
Aux/E 
Auxiliary/Emergency heat relay
Sends output when set to Em. Heat 
[11]
2H/1C Heat Pump  
System  
(TH5320U only)
 
[8]
Rc 
Power 
[1]
[R+Rc joined by jumper]
Compressor contactor
24VAC common 
[3]
O/B 
Changeover valve 
[7]
Fan relay
Aux/E 
Auxiliary/Emergency heat relay
Sends output when set to Em. Heat 
[11]
2H/2C Heat Pump  
System  
(TH5320U only)
 
[9]
Rc 
Power 
[1]
[R+Rc joined by jumper]
Compressor contactor (stage 1)
24VAC common
 [3]
O/B 
Changeover valve
 [7]
Fan relay
Y2 
Compressor contactor (stage 2)
Sends output when set to Em. Heat 
[11]
3H/2C Heat Pump  
System  
(TH5320U only)
 
[10]
Rc 
Power 
[1]
[R+Rc joined by jumper]
Compressor contactor (stage 1)
24VAC common 
[3]
O/B 
Changeover valve 
[7]
Fan relay
Aux/E 
Auxiliary/Emergency heat relay
Y2 
Compressor contactor (stage 2)
Sends output when set to Em. Heat 
[11]
See Notes on page 3.
Rc
Y
G
Aux
E
L
R
C
Rc
Y
G
Aux
E
L
R
C
Rc
Y
G
Y2
L
R
C
Rc
Y
G
Aux
E
L
R
C
Y2
Wiring heat pump systems
Shaded areas below apply only to 
TH5320U/TH5220D