Preparing for Forward Path Balancing 
Note: Consult your system technical supervisor or manager for more information 
about which choice of setup mode to use as this may be dictated by your system or 
corporate engineering policy. 
Switch S1 Position Information for Thermal Configured Stations 
Position 1 
Amplifier Only 
Position 2 
NOT USED 
Position 3 
Amplifier and Coax 
A thermistor (thermal) driven 
circuit on the amplifier sets the 
DC control voltage that drives 
the Bode. 
This circuit detects the 
amplifier’s internal temperature 
and generates the proper level 
of DC control voltage, setting 
the proper loss characteristics of 
the Bode with respect to the 
current outdoor temperature. 
Note:
 This switch position is 
meant to compensate for the 
temperature related level 
variations of the amplifier only.  
This switch position is normally 
selected when underground 
cable precedes the station, since 
such cable is subject to little 
temperature variation. 
Important! Do not select this 
position. This position is reserved 
for stations with an AGC installed. 
While adjustments to the Manual 
Backoff potentiometer will affect 
amplifier gain with S1 in this 
position, once S1 is set to position 
1 or 3, the manual potentiometer 
setting will not affect proper 
thermal amplifier operation. 
Leaving the switch in this position 
disables the thermistor (thermal) 
driven circuit and enables the 
backoff potentiometer on the 
amplifier.  This sets the DC control 
voltage that drives the Bode to a 
constant setting, regardless of the 
current outdoor temperature. 
Note: This is a factory setting used 
to verify proper station gain with a 
given amount of manual gain 
backoff. 
A thermistor (thermal) driven 
circuit on the amplifier sets the DC 
control voltage that drives the 
Bode. 
This circuit detects the amplifier's 
internal temperature and 
generates the proper level of DC 
control voltage, setting the proper 
loss characteristics of the bode 
with respect to the temperature. 
Note:
 This switch position is 
meant to compensate for the 
temperature related level 
variations of both the amplifier 
and the coaxial cable preceding 
the station. 
This switch position is normally 
selected when overhead cable 
precedes the station, since such 
cable is subject to temperature 
variation. 
Note: Switch S1 in Position 2, and the backoff potentiometer, are used in AGC stations only. 
 
To Verify the Input Signal Level 
Complete the following steps to test the input signal level. 
Important: You cannot balance the amplifier without the proper input signals. 
1  Connect the test equipment to the forward input test point shown in the 
illustration below. 
 
 
OL-31156-01 
49