Chapter 3    Balancing and Setup 
 
 
 
2  Measure the signal level at the following frequencies: 
 
The lowest frequency specified in the system design 
 
The highest frequency specified in the system design 
3  Compare the measured levels to the design input levels on the system design 
print. 
Note: Add 20 dB to the measured levels to find the true levels. The test point 
attenuates input signals by 20 dB. 
4  Are measured levels within the desired limits? 
 
If yes, proceed to step 5. 
 
If no, or if no signals are present, find the problem before proceeding. You 
cannot balance the amplifier without the proper input signals. 
5  Remove the test point adapter from the forward input test point, leaving other 
equipment connectors intact. 
 
 