Balancing the Forward Path 
Balancing the Forward Path 
Be sure to use the correct procedure for forward path balancing. Refer to To Select the 
Forward Path Balancing Procedure (on page 51) for help in identifying the procedure 
that best fits your system installation and amplifier type. 
Before you begin, also make sure that the amplifier module is configured according 
to the specifications in the design print, and that the amplifier has warmed up for 
approximately one hour. 
 
To Select the Forward Path Balancing Procedure 
Refer to the following table to direct you to the proper starting point to balance your 
amplifier using your preferred method. 
If you have ... 
and you use ... 
go to ... 
an amplifier configured with 
AGC 
manual setup mode for 
balancing and operation 
Forward Path Balancing for 
AGC Stations Using Manual 
Setup Mode (on page 51) 
an amplifier configured with 
AGC 
thermal setup mode for 
balancing and operation 
Forward Path Balancing for 
AGC Stations Using Thermal 
Setup Mode (on page 58) 
a thermal amplifier (no 
AGC) 
amplifier only compensation 
mode for balancing and 
operation 
Forward Path Balancing for 
Thermal Stations Using 
Amplifier Only Compensation 
Mode (on page 64) 
a thermal amplifier (no 
AGC) 
amplifier and coax 
compensation mode for 
balancing and operation 
Forward Path Balancing for 
Thermal Stations Using 
Amplifier and Coax 
Compensation Mode (on page 
67) 
an amplifier configured with 
AGC 
a trim network for balancing 
Forward Path Balancing Using 
Trim Networks (on page 71) 
 
Forward Path Balancing for AGC Stations Using Manual Setup Mode 
Before you begin, make sure that you have configured the amplifier module 
according to the specifications in the design print, and that the amplifier has warmed 
up for approximately one hour. 
 
To Set the Manual Backoff Level 
You must adjust the manual backoff level. 
Complete the following steps to set the manual backoff level. 
 
OL-31156-01 