DLP-G259 Manual or Force Switch the Node Timing Reference
This task commands the node to switch to the timing reference
you have selected.
Purpose
None
Tools/Equipment
"DLP-G46 Log into CTC" task in
document.
Prerequisite Procedures
As needed
Required/As Needed
Onsite or remote
Onsite/Remote
Maintenance or higher
Security Level
Procedure
Step 1
In node view (single-shelf mode) or shelf view (multishelf mode), click the Maintenance > Timing > Source tabs.
Step 2
From the Reference drop-down list for the desired Clock, choose the desired reference.
Step 3
From the Operation drop-down list for the desired Clock, choose one of the following options:
• Manual -This operation commands the node to switch to the reference you have selected if the synchronization status
message (SSM) quality of the reference is not lower than the current timing reference.