Cisco Cisco Configuration Engine 3.5.3 Guía Para Resolver Problemas

Descargar
Página de 30
Troubleshooting Guide for Cisco Configuration Engine 3.5.3
Troubleshooting a Configuration Update
13
Troubleshooting Guide for Cisco Configuration Engine 3.5.3
OL-17767-03
Note
You cannot see the password setting after you have configured it on the router, nor can you edit the 
password in Cisco CE. Therefore, you must reset the password. To reset the password, use the resync 
device feature in Cisco CE.
Step 8
If you have tried all of the preceding steps but the initial configuration still does not work, use the 
debug cns config all command to enable debugging on the agent. Analyze the output to verify that the 
agent is set up correctly with proper connectivity. 
Step 9
If the initial configuration still does not work, reboot the device. 
Monitor Event Traffic and Cisco CE Process Status
Use the following log files to monitor event traffic and Cisco CE process status:
/var/log/CNSCE/cfgsrv/cfgsrv.log, error.log—Check the cfgsrv log file when the config agent is 
enabled and initial configuration is issued on the device. 
/var/log/CNSCE/evtgateway/TibGateLog-<port>—Check the TibGate log file when the event agent 
is enabled on the device.
/var/log/httpd/*.log, /var/log/CNSCE/tomcat/*.out, *.txt, *.log—Check the Apache & Tomcat log 
files to make sure that the web server is running properly.
/var/log/CNSCE/appliance-setup.log—Check the setup log file for Cisco CE set up, especially in 
crypto set up mode. 
/var/log/CNSCE/websvc—Check the web service log file to see whether the application 
programming interface (API) is invoked. 
Troubleshooting a Configuration Update
To troubleshoot a configuration update, see the following sections:
CNS-Enabled Device Unable to Connect with Cisco CE
Problem
A device is created in the Cisco CE user interface but the device indicator displays a red status. 
Possible Cause
The red status indicates that the device is unable to connect with Cisco CE or it is 
still trying to connect. A connection delay can occur due to the device setting of the backoff timer. 
After the time has expired, the indicator does not turn to green, follow the steps given below.
Solution
To resolve this problem, follow these steps: