Step 2: Attach the Outer Slide Rails to the Rack 
Caution! Lifting the unit and attaching it to the rack is a two-person job. If 
needed, use an appropriate lifting device. A fully loaded SV Director Server 
weighs approximately 51.5 lb (23.4 kg). 
Note: This procedure describes the installation of the outer slide rails to a 4-post 
threaded-hole rack. If your 4-post rack uses rectangular holes, ensure that you 
have the proper adapters in place to secure the slide rails to the posts. 
To attach the outer slide rails to the rack: 
1.  Determine the position on the rack where you want to mount the server. 
2.  Position the rear-mounting bracket on the outer side of the rear rack post and 
attach with the 10-32 x 1/2-inch rack screws. 
3.  Align the center end of the outer slide rail to the corresponding hole on the 
front rack post. 
4.  Attach the front-mounting bracket of the outer slide rail to the corresponding 
holes on the front rack post with the 10-32 x 1/2-inch rack screws. 
5.  Repeat Steps 2 through 4 for the other outer slide rail. 
6.  Proceed to 
 
Step 3: Install the Server into the Rack 
Caution! If you mount the outer slide rails in holes that are not vertically aligned 
from front to back, you might damage the slide rails and your mounting might not 
be secure. 
To install the server into the rack: 
1.  Extend the inner slide rail until it locks into place. 
2.  Position the chassis so that the rear end of the inner slide rail aligns with the 
front end of the outer slide rails. 
3.  Slide the chassis into the rack. You may need to press on the release spring. 
See location 1 in Figure 29. 
Figure 29.  Installing the Chassis  in the Rack